dehydration_metadata_v1 / distribution_system_assets / distribution_transformers

Transformer Item

Type: object Additional Properties Allowed: True

Property Type Required Format Title
kva integer ✅ Capacity in kVA
count integer ✅ Transformer Count
is_regulator boolean ✅ Is Regulator
is_substation_transformer boolean ✅ Is Substation Transformer
num_phase integer ✅ Number of Phase
high_kv number ✅ High Voltage kV
low_kv number ✅ Low Voltage kV
avg_customers_served number ✅ Average Customers Served
min_customers_served number ✅ Minimum Customers Served
max_customers_served number ✅ Maximum Customers Served
std_customers_served number \| string ✅ Standard Deviation Customers Served
min_pct_peak_loading number ✅ Minimum Percentage Peak Loading
avg_pct_peak_loading number ✅ Average Percentage Peak Loading
max_pct_peak_loading number ✅ Maximum Percentage Peak Loading
std_pct_peak_loading number \| string ✅ Standard Deviation Percentage Peak Loading

kva

Transformer capacity on kVA.

  • is required
  • Type: integer

Minimum Number: 1

count

Number of transformers.

  • is required
  • Type: integer

Minimum Number: 1

is_regulator

True if regulator.

  • is required
  • Type: boolean

is_substation_transformer

Set to true if these are substation transformers.

  • is required
  • Type: boolean

num_phase

Transformer number of phase.

  • is required
  • Type: integer

Minimum Number: 1 Maximum Number: 3

high_kv

Kilovolt rating for high voltage side.

  • is required
  • Type: number

Minimum Number: 0.01

low_kv

Kilovolt rating for low voltage side.

  • is required
  • Type: number

Minimum Number: 0.01

avg_customers_served

Average number of customer served downward from these type of transformers.

  • is required
  • Type: number

Minimum Number: 0

min_customers_served

Minimum number of customer served downward from these type of transformers.

  • is required
  • Type: number

Minimum Number: 0

max_customers_served

Maximum number of customer served downward from these type of transformers.

  • is required
  • Type: number

Minimum Number: 0

std_customers_served

Standard deviation number of customer served downward from these type of transformers.

  • is required
  • Type: number | string

One Of

min_pct_peak_loading

Minimum percentage loading of these type of transformers during peak load.

  • is required
  • Type: number

Minimum Number: 0

avg_pct_peak_loading

Average percentage loading of these type of transformers during peak load.

  • is required
  • Type: number

Minimum Number: 0

max_pct_peak_loading

Maximum percentage loading of these type of transformers during peak load.

  • is required
  • Type: number

Minimum Number: 0

std_pct_peak_loading

Standard deviation percentage loading of these type of transformers during peak load.

  • is required
  • Type: number | string

One Of