dehydration_metadata_v1 / distribution_system_assets / distribution_feeder_sections
Feeder Section Item¶
Type: object
Additional Properties Allowed: True
Property | Type | Required | Format | Title |
---|---|---|---|---|
kv | number |
Feeder Section Voltage | ||
num_phase | number |
Feeder section number of phase. | ||
count | number |
Feeder Section Count | ||
avg_feeder_miles | number |
Average Feeder Miles | ||
min_feeder_miles | number |
Minimum Feeder Miles | ||
max_feeder_miles | number |
Maximum Feeder Miles | ||
std_feeder_miles | number \| string |
Standard Deviation Feeder Miles | ||
min_ampacity | number |
Minimum Feeder Ampacity | ||
avg_ampacity | number |
Average Feeder Ampacity | ||
max_ampacity | number |
Maximum Feeder Ampacity | ||
std_ampacity | number \| string |
Standard Deviation Feeder Ampacity | ||
avg_per_unit_resistance_ohm_per_mile | number |
Average Per Unit Resistance | ||
min_per_unit_resistance_ohm_per_mile | number |
Minimum Per Unit Resistance | ||
max_per_unit_resistance_ohm_per_mile | number |
Maximum Per Unit Resistance | ||
std_per_unit_resistance_ohm_per_mile | number \| string |
Standard Deviation Per Unit Resistance | ||
avg_per_unit_reactance_ohm_per_mile | number |
Average Per Unit Reactance | ||
min_per_unit_reactance_ohm_per_mile | number |
Minimum Per Unit Reactance | ||
max_per_unit_reactance_ohm_per_mile | number |
Maximum Per Unit Reactance | ||
std_per_unit_reactance_ohm_per_mile | number \| string |
Standard Deviation Per Unit Reactance | ||
min_customers_served | number |
Minimum number of customers served. | ||
avg_customers_served | number |
Average number of customers served. | ||
max_customers_served | number |
Maximum number of customers served. | ||
std_customers_served | number \| string |
Standard Deviation number of customers served. | ||
min_pct_peak_loading | number |
Minimum Percentage Peak Loading | ||
avg_pct_peak_loading | number |
Average Percentage Peak Loading | ||
max_pct_peak_loading | number |
Maximum Percentage Peak Loading | ||
std_pct_peak_loading | number \| string |
Standard Deviation Percentage Peak Loading |
kv¶
Kilo volt rating of feeder section. Line to line for multi phase and line to ground for single phase.
- is required
- Type:
number
Minimum Number: 0.01
num_phase¶
Number of phase for feeder section.
- is required
- Type:
number
Minimum Number: 1
Maximum Number: 3
count¶
Number of feeder section for given voltage rating, num of phase and construction type.
- is required
- Type:
number
Minimum Number: 1
avg_feeder_miles¶
Average feeder section length in miles.
- is required
- Type:
number
Minimum Number: 0
min_feeder_miles¶
Minimum feeder section length in miles.
- is required
- Type:
number
Minimum Number: 0
max_feeder_miles¶
Maximum feeder section length in miles.
- is required
- Type:
number
Minimum Number: 0
std_feeder_miles¶
Standard deviation feeder section length in miles.
- is required
- Type:
number | string
One Of¶
min_ampacity¶
feeder section ampere capacity.
- is required
- Type:
number
Minimum Number: 0
avg_ampacity¶
Average feeder section ampere capacity.
- is required
- Type:
number
Minimum Number: 0
max_ampacity¶
Maximum feeder section ampere capacity.
- is required
- Type:
number
Minimum Number: 0
std_ampacity¶
Standard deviation feeder section ampere capacity.
- is required
- Type:
number | string
One Of¶
avg_per_unit_resistance_ohm_per_mile¶
Average per unit resistance for feeder sections.
- is required
- Type:
number
min_per_unit_resistance_ohm_per_mile¶
Minimum per unit resistance for feeder sections.
- is required
- Type:
number
max_per_unit_resistance_ohm_per_mile¶
Maximum per unit resistance for feeder sections.
- is required
- Type:
number
std_per_unit_resistance_ohm_per_mile¶
Standard Deviation of per unit resistance for feeder sections.
- is required
- Type:
number | string
One Of¶
avg_per_unit_reactance_ohm_per_mile¶
Average per unit reactance for feeder sections.
- is required
- Type:
number
min_per_unit_reactance_ohm_per_mile¶
Minimum per unit reactance for feeder sections.
- is required
- Type:
number
max_per_unit_reactance_ohm_per_mile¶
Maximum per unit reactance for feeder sections.
- is required
- Type:
number
std_per_unit_reactance_ohm_per_mile¶
Standard Deviation of per unit reactance for feeder sections.
- is required
- Type:
number | string
One Of¶
min_customers_served¶
Minimum number of customers served directly or downward from this feeder section.
- is required
- Type:
number
Minimum Number: 0
avg_customers_served¶
Average number of customers served directly or downward from this feeder section.
- is required
- Type:
number
Minimum Number: 0
max_customers_served¶
Maximum number of customers served directly or downward from this feeder section.
- is required
- Type:
number
Minimum Number: 0
std_customers_served¶
Standard deviation number of customers served directly or downward from this feeder section.
- is required
- Type:
number | string
One Of¶
min_pct_peak_loading¶
Minimum percentage loading of these type of feeder sections during peak load.
- is required
- Type:
number
Minimum Number: 0
avg_pct_peak_loading¶
Average percentage loading of these type of feeder sections during peak load.
- is required
- Type:
number
Minimum Number: 0
max_pct_peak_loading¶
Maximum percentage loading of these type of feeder sections during peak load.
- is required
- Type:
number
Minimum Number: 0
std_pct_peak_loading¶
Standard deviation percentage loading of these type of feeder sections during peak load.
- is required
- Type:
number | string